Responsive Respiratory Respond O2 Dual Lumen Oxygen Conserver - 130-0505 - 4.8" L x 1.8" W x 1.4" H, 13.8 oz
Responsive Respiratory Respond O2 Dual Lumen Oxygen Conserver is a high-pressure oxygen regulator and conserving device that is combined into a single compact unit. It operates in the same manner as traditional oxygen pressure regulators with the added benefit of having a conserving device included. The system is designed for use by an ambulatory patient with a high-pressure oxygen cylinder. Since the Respond C5 requires no electrical (battery) power source, it is a reliable and easy to use the device.
Features
- Responsive Respiratory Respond O2 Dual Lumen Oxygen Conserver is a combined regulator and conserving device
- It provides therapy and conserves oxygen by delivering the patient;s prescribed liter flow only during inhalation
- The user can switch between Continuous and Conserve
- Mode simply by turning the knob
- The device has a compact one-piece aluminum body with all-brass in the high-pressure zone
- It includes a click-style flow control with 10 flow settings
- For additional safety and longer device life, it has a sintered bronze high-pressure inlet filter
- 3:1 Conservation Ratio {1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6}
- 100% conserver or regulator
- No confusing electronics
- Uses dual lumen cannulas
- Continuous flow at all settings
- Whisper quiet - ideal for church, movie or bingo outings
More Information
- Removal of the Respond C5 from the cylinder:
- Close the cylinder valve
- Set the adjusting knob to the lowest flow setting and allow the regulator to de-pressurize
- Be sure the contents gauge reads zero
- Remove regulator from cylinder valve - Cleaning and Maintenance:
- The exterior surfaces can safely be wiped off with a clean, lint-free cloth.
- If the cloth is dampened with water, do not let water enter the relief valve or vent holes - Warning:
- If grease or oil is visible or suspected to be present, DONOT use the device, and do not attempt to clean or repair it
- Have it serviced by qualified personnel
- If any leakage of the oxygen cylinder is detected, turn the valve stem or handle clockwise until the cylinder valve is closed
- If leakage persists, place the cylinder outdoors and notify the gas supplier immediately
Specification
Specification | |
Operating Pressure | 500 to 3000 PSIG |
Outlet Pressure Nominal | 22 PSI |
Selectable outlet flow | 1-5 LPM Conserving; 2-4 LPM continuous |
Oxygen Conservation | Nominal 75% at all setting based upon an avg I:E ratio |
Inlet Configuration | CGA 870 Pin Indexed Yoke |
Outlet connection | Cannula hose barb |
Unit Weight | 14 oz (0.9 lbs) |
Storage Temperature (degrees C) | -20 to 60 |
Operating Temperature (degrees C) | 0 to 40 |
Diameter gage | 1-1/4" |
Warranty
Three Years Warranty