Precision Medical EasyPulse5+6 Oxygen Conserving Regulator - 198712 - EasyPulse5+6
Precision Medical EasyPulse5+6 Oxygen Conserving Regulator has 6 continuous flow settings, to compliment the 1 thru 5 pulse settings. Even with the added continuous flow settings, it weighs in at a mere 9.9 oz and is only 4.75 inches long, making it still the smallest and lightest conserving regulator available. With the conserving ratio of up to 5.7 to 1, you enjoy the same great savings you have always enjoyed with the EasyPulse5. Why choose Easypulse5 6 Oxygen Conserving Regulator? Big Results in a Small PackageReduces DeliveriesCMV Technology
Easy Pulse5 Features
- Precision Medical EasyPulse5+6 Oxygen Conserving Regulator delivers a front loaded tapered waveform
- CMV Technology:
- All the oxygen is delivered in the first third of the inspiratory phase. With the added security of more continuous flow options, you have the most versatile oxygen conserving device available
- Certifications:
- It meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council and all applicable design and safety related standards
What to Buy With O2 Conserving Regulator?
How to clean Oxygen Conserving Regulator?
- Disconnect all connections before cleaning
- After each use, clean exterior of the Conserver with a clothdampened with mild detergent and water
- Wipe dry with a clean cloth
- Store the Conserver in a clean area free from grease, oil, and othersources of contamination
Warning:
- Ensure the compatibility of the oxygen conserving equipment and all of the parts and accessories used to connect to the patient before use
- Ensure that the oxygen delivery settings were determined and recorded for the patient individually together with the configuration of the equipment to be used, including accessories
- Periodically reassess the setting(s) of the therapy for effectiveness
- Always follow standards for Medical Gas Products and High-Pressure Oxygen Handling. In the United States, ANSI, CGA, and G-4 applies
- Keep cylinder valve closed at all times when cylinder is not in use
- NO OXYGEN is delivered when the pointer is aligned with OFF
- DO NOT USE without a seal. For optimum safety, use only a Precision Medical, Inc. InletSeal. The Inlet Seal supplied with the Conserver is reusable. DO NOT USE any othertype of seal
Contraindication:
- Should not be used for tracheotomised patient, patients who breathe through their mouths or oxygen masks and source of oxygen while sleeping
- DO NOT use if dirt or contaminants are present on or around cylinder, valve, theConserver or connecting devices
- DO NOT use oils, greases, organic lubricants or any combustible materials on or near theConserver. Wash and dry hands properly prior to use
- DO NOT use a humidifier with the Conserver
- DO NOT allow cylinders to tip or fall. Secure gas cylinders so they cannot fall. Foroptimum safety keep cylinder upright whenever possible
- DO NOT store cylinders near sources of heat or flame
- Smoking during oxygen therapy is dangerous and is likely to result in serious injury ordeath of the patient and others from fire
- There is a risk of fire associated with oxygen equipment and therapy. Do not use nearsparks or open flames
- Use only medical grade oxygen. In the United States, USP applies
Oxygen Therapy Regulator Specifications
Particulars |
Specification |
Dimensions |
Length:4.75 in (12.07 cm)
Width:2.63 in (6.7 cm)
Height:2.5 in (6..35 cm) |
Weight |
9.9 oz (.279 kg) |
Inlet Pressure Range |
300 - 3000 psig (2068 - 20684 kPa) |
Internal Regulated Pressure |
50 psig (345 kPa) |
Operating Altitude Range |
Sea level to 10,000 ft above sea level (Sea level to 3,048 m above sea level) |
Pulse Settings |
1, 2, 3, 4 and 5 |
Flow Settings |
1, 2, 3, 4, 5 and 6 L/min Continuous |
Savings Ratio |
Up to 5.7 : 1 |
Cannula Requirements |
Maximum 7 ft long adult standard single lumen oxygen nasal cannula |
Oxygen Cylinder Connections |
CGA 870 Post Valve |
Pulse Volume Chart
Setting |
Pulse Volume @ Rate Of
|
Minute Volume |
|
15 |
20 |
25 |
30 |
|
1 |
17 mL |
13 mL |
10 mL |
9 mL |
260 mL/min |
2 |
28 mL |
21 mL |
17 mL |
14 mL |
420 mL/min |
3 |
37 mL |
28 mL |
22 mL |
19 mL |
560 mL/min |
4 |
47 mL |
35 mL |
28 mL |
23 mL |
700 mL/min |
5 |
57 mL |
43 mL |
34 mL |
29 mL |
860 mL/min |
2 L/min |
N/A
|
2000 mL/min (2 L/min) |
Warranty