M8 Elite Portable Ultrasound System (03.12.00) - Standard Configuration includes: |
15.6" LED wide format HD 1920 x 1080 monitor |
256GB Solid State Hard Disk & iStation™ Patient Information Management |
HDMI Output, (2) USB 3.0 Ports and Integrated Wi-Fi |
Standard Software Included: |
B/M/Color/Color M/Power/Directional Power Doppler Flow Imaging |
Pulse Wave Doppler (includes High Pulsed Repetition Frequency) |
PSH™ (Phase Shift Harmonic Imaging) |
iBeam™ (Spatial Compounding Imaging) |
iClear™ (Speckle Suppression Imaging) |
iTouch™ (Auto Image Optimization) |
iZoom™ (Full Screen View) |
Echo BoostTM |
Qpath™ Access |
Shared Service Calculation Package (includes Abdomen/General, Obstetrics, Gynecology, |
Cardiac, Small Parts, Urology, Vascular, Pediatrics, Nerve, Emergency & Critical Care |
calculations.) |
HDR Flow (High Dynamic Range Flow) |
HR Flow (High Resolution Flow) |
Auto IMT Package |
DICOM Basic, HL7/ Worklist, DICOM OB/GYN S/R, DICOM Vascular S/R, DICOM Breast S/R |
iNeedle™ (Needle Visualization Enhancement) |
iWorks™ (Standardized Workflow Protocol) |
Peripherals Included: |
AC Adapter and Lithium-ion Battery Pack (Built-in Main Unit, 90 minute rating.) |
Ethernet adapter |
Travelling Case |
Includes 5 Year Warranty |
M8 Elite Portable Ultrasound System - Advanced Configuration: |
15" LED wide format HD 1920 x 1080 monitor |
256GB Solid State Hard Disk & iStation™ Patient Information Management |
HDMI Output, (2) USB 3.0 Ports and Integrated WiFi |
Standard Software Included: |
B/M/Color/Color M/Power/Directional Power Doppler Flow Imaging |
Pulse Wave Doppler (includes High Pulsed Repetition Frequency) |
PSH™ (Phase Shift Harmonic Imaging) |
iBeam™ (Spatial Compounding Imaging) |
iClear™ (Speckle Suppression Imaging) |
iTouch™ (Auto Image Optimization) |
iZoom™ (Full Screen View) |
Echo BoostTM |
Qpath™ Access |
Shared Service Calculation Package (includes Abdomen/General, Obstetrics, Gynecology, |
Cardiac, Small Parts, Urology, Vascular, Pediatrics, Nerve, Emergency & Critical Care |
calculations.) |
HDR Flow (High Dynamic Range Flow) |
HR Flow (High Resolution Flow) |
Auto IMT Package (Automatic measurement for Intima-Media Thickness, Vascular Package |
should be configured at the same time) |
Continuous Wave Doppler |
Free Xros M™ (Anatomical M-mode) |
TDI (Tissue Doppler Imaging, includes TVI, TEI, TVD and TVM) |
TDI QA Software (TDI should be configured at the same time) |
Tissue Tracking with Quantitative Analysis (Strain/Strain Rate) |
Stress Echo |
DICOM Basic, HL7, Worklist, Query/Retrieve, Vascular and Cardiac S/R |
iWorks™ (Standardized Workflow Protocol) |
ECG Lead (FDA) with physio function key (ECG/RCG function key) |
Peripherals Included: |
AC Adapter and Lithium-ion Battery Pack (Built-in Main Unit, 90 minute rating) |
Ethernet adapter |
Travelling Case |
Includes 5 Year Warranty |
Standard Software Kit V03.11.00 |
M8 Elite Software V03.12.00 Sales BOM Includes: |
M8 Elite Software/OS, V03.12.00 (part number 110-003431-12) |
M8 Elite Manuals Disk V03.12.00 (part number 110-003433-09) |
Software Options |
Continuous Wave Doppler HW Module (Included with Advanced Configuration) |
Free Xros M™ (Anatomical M-mode) (Included with Advanced Configuration) |
Tissue Tracking with Quantitative Analysis (Strain/Strain Rate) |
TDI (Tissue Doppler Imaging, includes TVI, TEI, TVD and TVM) (Included with Advanced |
Configuration) |
Free Xros CM™ (Curved Anatomical M-Mode, TDI should be configured at the same time) |
TDI Quantification Analysis Software (TDI should be configured at the same time) |
Stress Echo (Included with Advanced Configuration) |
LVO Contrast (Left Ventricle Opacification Contrast, available on SP5-1s) |
Contrast (CEUS for Abdominal) |
Contrast (CEUS QA) |
Elastography (available on L12-4s, L14-6Ns) |
iScape™ View (Real-time Panoramic Imaging) |
iNeedle™ (Needle Visualization Enhancement) |
Smart NT (automatic calculation of Nuchal Translucency, Obstetrics package should be |
configured at the same time) |
Smart OB™ (automatic measurements for BPD, FL, HC, AC and OFD, Obstetrics package |
should be configured at the same time) |
Auto EF (Automatically recognizes diastole/systole frames and output EDV/ESV/EF) |
Physio Function Key (ECG/RCG function key-requires ECG lead kit) |
(Included with Advanced Configuration) |
Smart 3D |
4D software |
iPage(Multi slice) |
Smart Volume |
ECG Lead Kit-includes ECG 3/5-lead cable, ECG 3-lead 36" pinch lead wire set and DC-IN cable |
(requires Physio Function Key) |
DICOM Options |
DICOM MPPS |
DICOM Query/Retrieve (Included with Advanced Configuration) |
DICOM OB/GYN S/R |
DICOM Vascular S/R (Included with Advanced Configuration) |
DICOM Cardiac S/R (Included with Advanced Configuration) |
DICOM Breast S/R |
Transducers |
C5-1s convex array transducer. Suggested applications: Adult Abdominal, Pediatrics |
Gynecology, Obstetrics, Vascular, Musculoskeletal. Bandwidth*: 1.4-5.1 MHz. Needle guide |
bracket: NGB-022 |
C6-2Gs convex array transducer. Requires software version 02.02.00 or higher. Suggested |
applications: Interventional, Fetal, Abdominal, Pediatrics. Bandwidth*: 1.7-6.0 MHz. Needle |
guide bracket: NGB-024 |
L10-3s linear array transducer. Requires software version 02.02.00 or higher. Suggested |
applications: Vascular, Small Parts, Musculoskeletal, Nerve. Bandwidth*: 2.7-10.5 MHz 4,300 |
L12-4s linear array transducer. Suggested applications: Small parts, Vascular, |
Musculoskeletal, Pediatrics, Neurology. Bandwidth*: 3.0-13.0 MHz. Needle guide bracket: |
NGB-007 |
L14-6Ns linear array transducer. Suggested applications: Small Parts, Vascular, Pediatrics, |
Musculoskeletal, Neurology. Bandwidth*: 3.5-16.0 MHz. Needle guide bracket: NGB-007 2,100 |
L14-6Ws linear array transducer. Requires software version 02.02.00 or higher. Suggested |
applications: Breast, Small Parts, Musculoskeletal, Nerve. Bandwidth*: 3.5-16 MHz. Needle |
guide bracket: NGB-007 |
L16-4Hs Linear Array Transducer Hockey Stick, Require software version 3.11.00 or higher |
Bandwidth*: 5-20MHz. 4,500 |
L20-5s linear array transducer, Require software version 3.11.00 or higher Bandwidth*: 4-16 |
MHz. |
SP5-1s single crystal phased array transducer. Suggested applications: Adult Cardiac, |
Pediatric Cardiac, Adult Cranial, Adult Abdominal. Bandwidth*: 1.1-4.4 MHz. Needle guide |
bracket: NGB-011 |
P7-3s phased array transducer. Requires software version 02.02.00 or higher. Suggested |
applications: Pediatric Abdominal, Pediatric Cardiac, Neonatal Cephalic, Neonatal Abdominal, |
Neonatal Cardiac. Bandwidth*: 2-8 MHz. |
P7-3Ts Multi Plane TEE Phased Array Transducer. Suggested application: Adult |
Transesophageal Echo. Bandwidth*: 1.9-8.2 MHz. 24,000 |
P8-3Ts Pediatric TEE Phased Array Transducer. Require software version 3.11.00 or higher |
Bandwidth*: 2.8-8.0Mhz 24,000 |
P10-4s phased array transducer. Suggested applications: Neonatal Cardiac, Pediatric Cardiac, |
Neonatal Abdominal, Pediatric Abdominal, Neonatal Cranial. Bandwidth*: 2.9-10.5 MHz. 3,500 |
V11-3Ws endocavity convex array transducer. Suggested applications: Gynecology, |
Obstetrics, Urology. Bandwidth*: 3.0-11.2 MHz. Needle guide bracket: NGB-004. 2,500 |
CW2s Non-imaging CW, Pedoff, Transducer. Suggested applications: Adult Cardiac, Pediatric |
Cardiac, Adult Cranial. CW Frequency: 2 MHz. 735 |
CW5s Non-imaging CW, Transducer. Suggested application: Vascular, Pediatric Cardiac. CW |
Frequency: 5 MHz |
C11-3s micro-convex array transducer. Suggested applications: Neonatal Cranial, Neonatal |
Abdominal, Pediatric Abdominal, Neonatal Cardiac, Pediatric Cardiac, Vascular, Neurology. |
Bandwidth*: 3.0-11.2 MHz. Needle guide bracket: NGB-018. |
D7-2s Volume convex array transducer. Require software version 3.11.00 or higher |
Bandwidth*: 1.6-7.2 MHz 6,500 |
* Frequency bandwidth measurements represent bandwidth at +/-20dB. |
Needle-guided brackets NGB-004 (stainless steel, undetachable, for 65EC10EA, 65EC10EB, |
65EC10EC, 65EC10ED, 65EC10HA, 65EC10HC, 65EC10HD, 65EB10EA, 6CV1(s), 6CV1P, V10- |
4(s), V10-4B(s), V10-4BP, CB10-4CB10-4P, CB10-4E, V11-3E, V11-3BE and V11-3WE) |
Needle-Guided brackets NGB-007 (stainless steel, detachable, for 7L4(s), 7L4A, 7L4P, 10L4(s), |
75L53EA, 75L53HA, 7L5(s), 7L5P, L7-3(s), L7-3E, L11-4(s), L12-4(s), L14-6Ns, L14-6NE, L12-3E, |
L14-6WE and L14-6Ws) |
Needle-Guided brackets NGB-007 (plastic, detachable, for 7L4(s), 7L4A, 7L4P, 10L4(s), |
75L53EA, 75L53HA, 7L5(s), 7L5P, L7-3(s), L7-3E, L11-4(s), L12-4(s), L14-6Ns, L14-6NE, L12-3E |
and L14-6WE) |
Needle-Guided Brackets NGB-011 (stainless steel, undetachable, for SP5-1s, 2P2(s), 2P2P, P4- |
2(s), P4-2E and P4-2NE) |
Needle-guide bracket NGB-018 (stainless Steel, detachable, for C11-3s and C11-3E) |
Needle-guide bracket NGB-022 |
Needle-guide bracket NGB-024 (stainless steel, detachable for C6-2Gs) |
Accessories |
Power cord (3.5m) |
AC adapter |
IOM-51, iDock (I/O Extended Module) |
M9 Lithium-ion Battery Pack |
ECG 3/5-lead cable, 10ft., adult/pediatric |
ECG 3-lead 36" pinch lead wire set, adult/pediatric |
ECG cable, neonatal |
DC-IN cable |
Water-resistant footswitch with two hot keys (USB port) |
Water-resistant footswitch with three hot keys (USB port) |
Ethernet adapter |
1D Barcode reader (USB port) |
2D Barcode reader (USB port) |
Sony Black & White Analog/Digital Printer |
Sony Color Digital Video Printer |
Soft transport roller bag |
Hard case transport roller bag (included with M9) |
Protective film cover for control panel |
UMT-500 Plus Cart |
UMT-500 Plus mobile cart with extended life Lithium-ion Battery Pack (Additional 120 minute |
rating) and integrated locking system. |
Mobile work platform includes handle, cable routing, transducer holders and storage |
Storage for fully integrated B/W and Color Printer |
Power Supply Module |
Mobile Cart Accessories |
PEM-51, transducer Extend Module for triple transducers connectors |
DVD Reader/Writer |
UMT-500 Plus battery |