Drive DeVilbiss 10L Oxygen Concentrator:   Drive DeVilbiss 10L Oxygen Concentrator is designed to provide optimal oxygen delivery for patients with varying flow requirements. It's intended use is to provide supplemental low flow oxygen therapy for patients suffering from COPD, cardiovascular disease, and lung disorders. The oxygen concentrator is used in home type environments, homes,...


$1,399.99
Prescription Required
Already on file
I will email to: prescription@eemedicals.com
I will fax 770-485-6251

Drive DeVilbiss 10L Oxygen Concentrator:
 

Drive DeVilbiss 10L Oxygen Concentrator is designed to provide optimal oxygen delivery for patients with varying flow requirements. It's intended use is to provide supplemental low flow oxygen therapy for patients suffering from COPD, cardiovascular disease, and lung disorders. The oxygen concentrator is used in home type environments, homes, nursing homes, patient care facilities, etc.

 

Drive DeVilbiss 10L Oxygen Concentrator Features:

 

  • Drive DeVilbiss 10L Oxygen Concentrator is built in the same shell as the 5 Liter, and also compatible with cylinder transfer systems
  • Substantially smaller and lighter than competitive 10 Liter concentrators
  • Capable of delivering 87% to 96% of O2 purity from 2 to 10 LPM, the 10 Liter Concentrator is an ideal investment for patients
  • Exclusive DeVilbiss OSD (Oxygen Sensing Device), standard on every unit, monitors the oxygen produced and ensures patient safety and reliability for longer service intervals
  • Equipped with accessible patient controls, bright LEDs that can be seen from a distance, protected cannula fitting and recessed humidifier nook to prevent damage
  • Sold separately, the Transfill Caddy is designed with a steel frame to simply connect the 18 x 14-inch shelf, designed to support up to 40 lbs., to the DeVilbiss 10L Concentrator

More Information about Drive DeVilbiss 10L Oxygen Concentrator:

 

  • How DeVilbiss Oxygen Concentrator Works:

-Oxygen concentrators are the most reliable, efficient and convenient source of supplemental oxygen available today. The oxygen concentrator is electrically operated. The unit separates oxygen from room air which allows high-purity supplemental oxygen to be delivered to you through the oxygen outlet. Although the concentrator filters the oxygen in a room, it will not affect the normal amount of oxygen in your room.

Warning:
- Oxygen causes rapid burning. Do not smoke while your oxygen concentrator is operating, or when you are near a person utilizing oxygen therapy.
- Oxygen makes it easier for a fire to start and spread. Do not leave the nasal cannula or mask on bed coverings or chair cushions if the oxygen concentrator is turned on but not in use. The oxygen will make the materials flammable. Turn the oxygen concentrator off when not in use to prevent oxygen enrichment.
- Keep the oxygen concentrator and cannula at least 2 m (6.5 feet) from hot, sparking objects or naked sources of flame.
- Open flames during oxygen therapy are dangerous and are likely to result in fire or death. Do not allow open flames within 2 m of the oxygen concentrator or any oxygen-carrying accessories.
- Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide.
- Smoking during oxygen therapy is dangerous and is likely to result in facial burns or death. Do not allow smoking within the same room where the oxygen concentrator or any oxygen-carrying accessories are located.
- If you intend to smoke, you must always turn the oxygen concentrator off, remove the cannula and leave the room where either the cannula or mask or the oxygen concentrator is located. If unable to leave the room, you must wait 10 minutes after you have turned off the oxygen concentrator before smoking.
- In order to prevent a fire propagating from the patient through the cannula towards the unit, a means of protection should be located as close to the patient as practicable. Please contact your provider for this means of protection.
- DeVilbiss 10-liter oxygen concentrators are equipped with a fire mitigating outlet fitting that prevents propagation of fire into the unit.
- To avoid electric shock, do not remove the concentrator cabinet. The cabinet should only be removed by a qualified DeVilbiss technician. Do not apply liquid directly to the cabinet or utilize any petroleum-based solvents or cleaning agents.
- Improper use of the power cord and plugs can cause a burn, fire or other electric shock hazards. Do not use the unit if the power cord is damaged.
- The surface temperature of the exhaust vents on the bottom of the unit may exceed 105.8?F (41 ?C) under certain conditions.
- When device is used under extreme operating conditions, the temperature near the exhaust vents on the bottom of the unit may reach 138.2°F (59°C). Keep body parts a minimum of 30” away from this area.
- Use of this device at an altitude above 5000 feet (1524 meters) or above a temperature of 95°F (35°C) or greater than 93% relative humidity may affect the flow rate and the percentage of oxygen and consequently the quality of the therapy. Refer to specifications for details regarding parameters tested.
- It is recommended that the homecare provider lock the flow control knob to prevent inadvertent adjustment. A flow setting other than prescribed may affect the patient therapy.
- To ensure you receive the therapeutic amount of oxygen delivery according to your medical condition, The Oxygen Concentrator must: - If you feel discomfort or are experiencing a medical emergency while undergoing oxygen therapy, seek medical assistance immediately to avoid harm.
- Geriatric, pediatric or any other patient unable to communicate discomfort can require additional monitoring and/or a distributed alarm system to convey the information about the discomfort and/or the medical urgency to the responsible caregiver to avoid harm.
- For your safety, the oxygen concentrator must be used according to the prescription determined by your physician.
- Under certain circumstances, oxygen therapy can be hazardous. Seek medical advice before using an oxygen concentrator.
- Before attempting any cleaning procedures, turn the unit "Off".
- Do not service or clean this device while in use with a Patient.
- Use of harsh chemicals (including alcohol) is not recommended. If bactericidal cleaning is required, a non-alcohol based product should be used to avoid inadvertent damage.
- Use only water-based lotions or salves that are oxygen-compatible before and during oxygen therapy. Never use petroleum or oil-based lotions or salves to avoid the risk of fire and burns
- Do not lubricate fittings, connections, tubing or other accessories of the oxygen concentrator to avoid the risk of fire and burns.
- Use only spare parts recommended by the manufacturer to ensure proper function and to avoid the risk of fire and burns.
- Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into service according to the Electromagnetic Compatibility [EMC] information provided in the accompanying documents.
- Portable and Mobile RF Communications Equipment can affect Medical Electrical Equipment.
- Installation of 515LF-607 low output flow meter package will cause the low flow alarm to not work.
- The Device is classified as IP21 which means it is protected against finger access to hazardous parts and protected against vertically falling water drops.
- The equipment or system should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, the equipment or system should be observed to verify normal operation in the configuration in which it will be used.
- This device contains electrical and/or electronic equipment. Follow local governing ordinances and recycling plans regarding disposal of device components.

-be used only after one or more settings have been individually determined or prescribed for you at your specific activity levels.

-be used with the specific combination of parts and accessories that are in line with the specification of the concentrator manufacturer and that were used while your settings were determined.

 

Drive DeVilbiss 10L Oxygen Concentrator Specification:

 

Particulars

Dimensions

Outlet Pressure

20.0 ? 1.0 psi (138 kPa +/- 7 kPa)

Oxygen Percentage 2-10 LPM, 87-96%
Delivery Rate 2.0 to 10.0 LPM

Electrical Rating

120 V, 60 Hz, 6.1 Amp

Operating Voltage Range

102-132 V~, 60 Hz

Oxygen Percentage 2-10 LPM=87% - 96%
Operating Altitude

(tested at 70?F {21?C} only) 0-1500 M (0-5000 ft)

Operating Environment Range 41?F (5?C) to 95?F (35?C), humidity range of 15% to 93% noncondensing
Power Consumption

120 vac, 60HZ: 639 watts average

Weight

42 lbs. (19 Kilograms)

Safe Working Load

53 lbs. (24 Kilograms)

Dimensions

24.5"H x 13.5"W x 12"D
(62.2 x 34.2 x 30.4 cm)

Maximum Limited Pressure

35 PSIG (241 kPa)

Operating System

Time Cycle / Pressure Swing

The visible ?low oxygen? indicator will activate at the following level

86% ? 3% (The audible alarm will alert at approximately 85%. At less than 60%, the red ?service required? light will activate.)
Storage Conditions -13?F (-25?C) to 158?F (70?C), humidity range of 15% to 93% non-condensing, including condensation

 