Drive 540 Mini Oxygen Regulator - 18303GM - 0-8 lpm Mini Regulator
  • Drive 540 Mini Oxygen Regulator - 18303GM - 0-8 lpm Mini Regulator

Drive 540 Mini Oxygen Regulator - 18303GM - 0-8 lpm Mini Regulator

P11068

Drive 540 Mini Oxygen Regulator - 18303GM - 0-8 lpm Mini RegulatorDrive 540 Mini Oxygen Regulator offers the same function as standard regulators while facilitating an easier fit into oxygen carry bags. It is easy-to-operate single selector knob. It features a protective contents gauge and a built-in pressure relief valve for safety. Drive 540 Mini Oxygen Regulator  is lightweight and durable...


$49.99


Drive 540 Mini Oxygen Regulator - 18303GM - 0-8 lpm Mini Regulator

Drive 540 Mini Oxygen Regulator offers the same function as standard regulators while facilitating an easier fit into oxygen carry bags. It is easy-to-operate single selector knob. It features a protective contents gauge and a built-in pressure relief valve for safety.


Drive 540 Mini Oxygen Regulator  is lightweight and durable
  • For use with: M60, M90, MM, H, J, T Cylinders
  • Meet or exceed accuracy standards for ASTM, American National, and CGA
  • Easy to operate single selector knob
  • Inlet Pressure: 300 - 3,000 PSI
  • Outlet pressure: 50 PSI
  • UL Approved
  • Liter Flow Increments:
    18303GM: 0.12, 0.5, 1, 1.5, 2, 2.5, 3, 4, 6, 8
    18304GMN: 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12, 15

  • More Information

    • How to set up:
      - Inspect the cylinder following the instructions of your gas supplier. Be sure to purge the cylinder valve seat of debris
      - Inspect the regulator for oil or grease. If these are visible, DO NOT use the regulator
      - Gently thread the large nut on the regulator onto the connection on the cylinder valve
      - Tighten the nut with a wrench until snug
      - Attach the oxygen supply tubing to the barb or DISS outlet of the regulator
    • Usage:
      - Be sure the regulator is in the off position by rotating the knob counterclockwise to the 0 position
      - For safety, be sure you are not directly in front of or behind the regulator when opening the cylinder valve
      - SLOWLY turn the cylinder valve (counter-clockwise) about one full turn
      - If you can hear a hissing sound, there is aleak in the system. Turn the cylinder off andturn the regulator on to relieve any built uppressure. Try tightening the regulator to thecylinder and opening the cylinder again.If this does not help, shut the system downagain and contact a service representative.NEVER attempt to repair a regulator orcylinder yourself
      - Adjust the flow rate setting by turning theknob clockwise until the prescribed settingshows through the window
      - If the cylinder pressure falls below 300PSI, you should exchange the cylinder fora full one
      - Use only on breathing patients
      - Do not smoke in an area where oxygen is inuse