Shopping Cart: 0 items
Your cart is empty.
MENU
DreamStation BiPAP Pro Machine - DSX600H11
  • DreamStation BiPAP Pro Machine - DSX600H11
  • DreamStation BiPAP Pro Machine - DSX600H11
  • DreamStation BiPAP Pro Machine - DSX600H11
  • DreamStation BiPAP Pro Machine - DSX600H11

DreamStation BiPAP Pro Machine - DSX600H11

DSX600H11

DreamStation BiPAP Pro Machine With humidifier ( DSX600H11 ) DreamStation BiPAP Pro Machine ( DSX600H11 ) combines pressure relief technology with optional humidification to increase comfort on a dual pressure machine. Bi-Flex is built into the device to soften the transition between the higher IPAP and the lower EPAP. Warm air from the humidifier and water chamber is provided to ...


$1,528.00
Prescription Required
Already on file
I will email to: prescription@eemedicals.com
I will fax 770-485-6251

DreamStation BiPAP Pro Machine With humidifier ( DSX600H11 )



DreamStation BiPAP Pro Machine ( DSX600H11 ) combines pressure relief technology with optional humidification to increase comfort on a dual pressure machine. Bi-Flex is built into the device to soften the transition between the higher IPAP and the lower EPAP. Warm air from the humidifier and water chamber is provided to therapy air by integrating the optional heated humidifier with the machine. It is designed to increase patient acceptance and adherence while creating workplace efficiencies for the user and staff. What Does DreamStation BiPAP Machine include?DreamStation Heated Humidifier Power Supply Power CordCarrying Case CPAP Hose SD Card Reusable Blue Pollen FilterUser Manual Disposable Light-Blue Ultra-Fine Filter.

 

DreamStation BiPAP Pro Features:

 

  • Intuitive menu system: Graphics based menu inspired by smartphone navigation for ease of use 
  • Ambient light sensor: Automatically adjusts screen brightness for daytime or nighttime viewing 
  • Top-mounted hose outlet: Swivel outlet rotates 180? for freedom of movement 
  • Detachable humidifier: The humidifier separates to travel even lighter 
  • Simplified design: Easy access to water chamber for filling and cleaning 
  • Integrated Bluetooth: Wirelessly connects with DreamMapper or Alice NightOne portable sleep diagnostic system 
  • Daily progress feedback: Displays previous 3 nights therapy results to track progress 
  • SD Card and compliance codes: Easily share sleep data with the care team 
  • Two-step air filtration system: Ultra-fine filter provides additional filtration of very fine particles Has a powerful suite of features to support business and patients. Has an accessible and user-friendly menu designed to provide alerts and sleep results for CPAP users

 

DreamStation BiPAP Pro Machine Benefits:

 

Optional Heated Humidifier

  • Integrate the machine and humidifier to help relieve dryness and congestion. With the unique ;Preheat; feature, the humidifier can begin warming the water chamber 30 minutes before the intended use. Ensure the blower is turned OFF and the humidifier is connected before selecting to preheat the device. The DreamStation device has the flexibility to be updated while in operation. Use the control dial to change the tube temperature or humidification settings. Please Note: The screen does not have touch screen capabilities
     

Bluetooth Connection to DreamMapper App Please

Note: The results are only available on one device at a time
 

  • The DreamStation CPAP has a built-in bluetooth connection which allows the device to pair directly with the Philips Respironics DreamMapper mobile and web-based program. Enable the bluetooth feature and download the SleepMapper app onto a smartphone or tablet (not included) to begin reviewing detailed sleep results. The free app gives the user the opportunity to personalize the data tracking account.

EZ-Start Technology

  • Designed to reduce the user;s prescribed pressure setting during the first 30 days of operation. The intent is to adjust the user to the pressure by beginning with half of the prescribed pressure
  • Please Note: A minimum pressure of 5cm H2O is required to use the EZ-Start feature
  • After obtaining a successful session of 4 or more hours of sleep, EZ-Start will gradually increase the pressure by 1cm H2O. This process will continue for 30 days until the user reaches their recommended pressure. If the goal is not met before the first 30 days, EZ-Start is designed to begin increasing 1cm H2O per day until reaching the prescribed pressure. At the prescribed pressure, the machine will move into normal CPAP mode. To enable or disable EZ-Start, the machine must be in CPAP mode
     

Bi-Flex Pressure Relief

  • Feature used to create a more natural breathing pattern during CPAP therapy. The DreamStation BiPAP Pro uses Flex Technology to provide relief during three points in the breathing cycle. Pressure is reduced by 0.5 increments during the transition from exhalation to inhalation, inhalation to exhalation, and during exhalation. The Bi-Flex setting can be adjusted up to 1.5 cm H2O for maximum comfort.
     

Ramp and SmartRamp

  • Ramp is intended to gently increase CPAP pressure from half of the prescribed pressure to the full pressure within a chosen period of time. To operate the Ramp feature, a CPAP pressure of 4cm H2O is required. Then, choose a time ranging from 5 minutes to 45 minutes to allow the machine to build the pressure in increments of 0.5cm H2O before reaching the prescribed pressure
  • In BiPAP mode, SmartRamp uses an Auto algorithm to balance lower inhalation and exhalation pressures. The device begins the Ramp process with a reduced exhalation pressure. Changes to the pressure are made on a breath by breath basis, until an event is detected. Once the BiPAP Pro detects an event, the machine will return to the BiPAP mode in order to deliver the recommended EPAP and IPAP. If the minimum prescribed pressure is not reached before Ramp is complete, the pressure will increase by 1 cm H2O each minute until the device reaches the recommended pressure
     

Advanced Event Detection

  • PR uses a patented algorithm to monitor breathing patterns implemented to respond to abnormal pressure changes. The Auto-Trak system in this machine measures variable triggers and cycle thresholds to automatically adjust the pressure and compensate for leakage. This machine is designed to act proactively by identifying aspects of the breathing cycle.
  • Upon detecting an event, the REMStar Auto algorithm is set to respond by automatically adjusting pressure levels to clear the apnea. Within a few seconds, the DreamStation BIPAP Pro begins pulsing a series of pressures to determine if the apnea has been cleared

Proactive Performance:

  • Proactive performance recognizes and controls early symptoms of flow limitation, which can lead to an actual obstruction or apnea. The Auto algorithm uses two airflow measurements to prevent pressures from becoming too high

Leak Management:

  • The DreamStation BiPAP will monitor mask leaks and compare results against an expected leak rate. Pressure is adjusted automatically as needed to help maintain therapy pressure to the user, including the ability to reduce pressure to help re-establish a mask seal

Obstructive Sleep Apnea:

  • OSA is defined as events that reduce 80% of airflow for a minimum of 10 seconds

Hypopnea:

  • A hypopnea is an event that reduces 40% of airflow for a minimum of 10 seconds

Flow Limitation:

  • Flow limitation is measured through four different baselines of the breathing waveform: Roundness, Flatness, Peak, and Shape

Vibratory Snoring:

  • Snoring can sometimes imitate a hypopnea event. Advanced detection allows this machine to measure vibrations and partial airway blockage

RERAs:

  • Respiratory Effort-Related Arousals differ from a hypopnea or snoring event in that a RERA shows increasing respiratory effort with each breath, culminating in a shift in brain wave activity and not necessarily a result of obstruction. Periodic breathing conditions such as Cheyne-Stokes respiration and central apneas are distinguishable from obstructed apnea or snoring events

SmartRamp:

  • SmartRamp helps manage apnea events while users attempt to fall asleep. This DreamStation BiPAP Pro device can react to an event as the Ramp is progressing
     

LCD On-Screen Display

  • PRs DreamStation Series was built with a simplistic and practical LCD screen. While the User Interface is in use, the screen is well lit. As the lights in the room are dimmed, the screen;s sensor is designed expel the light from the screen
  • Please Note: The control dial is used to view the menu. The screen does not have touch screen capabilities
  • Sleep results are posted on the User Interface to display results and goals for sleep therapy
  • The first screen accounts for a "Three Night Summary" which is determined after 12pm on the third day of treatment. Refer to the User Interface to view the results as they update each day
  • Daily sleep compliance results are provided after the most recent session. If the user sleeps 4 or more hours, the session is considered successful, rendering a green bar on the right side of the screen. If the user does not reach the anticipated 4 hour mark, the therapy will be noted by a yellow bar in the right corner of the screen
  • The second screen is in place for the first 90 days unless the sleep goal is met before the completion of this time. The data details the number of compliant nights recorded over the previous 30 days. A minimum of 21 successful four hour nights is needed to reach the 70% desired goal in order to surpass the screen before the end of 90 days

Philips Respironics Dry Box

  • Dry Box technology was created to help reduce the chance of water. 
  • See more Products on eemedicals.
     
    THIS ITEM REQUIRES A PRESCRIPTION
    If you do not have a prescription at time of purchase, a sales associate will reach out to you prior to delivery.

Current Reviews: 0