Devilbiss PulmoMate Compressor Nebulizer System - 4650D - Devilbiss PulmoMate 3.8"H X 7"W X 13"D
Devilbiss PulmoMate Compressor Nebulizer System is designed to provide most effective aerosol treatment. Air compressor offers a source of compressed air for home health care use. Compressor is used with a jet nebulizer to convert inhalable drugs into an aerosol form. Pulmomate 4650D can be used with both adults and pediatrics.PulmoMate Compressor Nebulizer System HighlightsPortable and lightweightCompressor free air flow ? 13 lpmMaximum compressor pressure ? 35 psigMetal frame motor constructionIntegrated handle for easy carryingBuilt in storage compartment
Pulmomate Compressor Nebulizer System Features
- Sturdy piston pump compressor nebulizer system
- Delivers an optimal and consistent pressure flow for the most effective aerosol treatment
- Consistent performance over the life of the unit
- Intuitive design is easy to use and maintain
- Built in storage compartment holds nebulizer cup and tubing while not in use
- Updated compressor motor for long-term durability and performance
- Low voltage protection with its 3 pronged plug
- Sleek, narrow compressor frame design fits into luggage or backpacks for easy carrying
- Durable handle means even without a carrying case user can still transport
- Durable nebulizer is used for aerosol therapy
- Flip-top access to control and supply storage
- Received a UL rating, demonstrating it has been safety tested
VixOne Nebulizer Features
- MMAD of 2.7 microns
- Respirable Fraction ? 84% below 5 microns
- At least 18% more medication delivered
- 7 feet kink-resistant flex hose tubing
- Low residual volume (0.7cc)
- High capacity medication bowl (>10cc)
- Comfortable mouthpiece design
- Anti-spill design provides secure seal
- Nebulizes in upright position or at angles up to 45 degrees to enhance comfort during treatment
- Universal connector accommodates standard adult and pediatric
PulmoMate Compressor Nebulizer System Guides
How To Operate Pulmomate Compressor Nebulizer?
- Put Devilbiss Pulmomate Compressor Nebulizer 4650D on a leveled surface such that the controls can be reached when seated. Never block the air openings or place it on a soft surface, such as lap or bed where the air openings may block.
- Open door to storage compartment.
- Make sure the power switch is in the "Off" position. Unwrap power cord and plug power cord into an appropriate wall outlet. Plug model 4650D into a grounded wall outlet.
- Wash hands.
- Connect one end of the nebulizer tubing to the compressor air-outlet connector
- Assemble clean nebulizer and add prescribed medication.
- Assemble mouthpiece, t-piece and corrugated tubing. Insert them into the top of the nebulizer cap. If using an aerosol mask, insert the bottom part of the mask directly into the top of the nebulizer cap.
- Attach tubing to nebulizer air-inlet connector.
- Press the power switch "On" to start the Pulmomate Nebulizer 4650D.
- Begin treatment by placing the mouthpiece between teeth. With mouth closed, inhale deeply and slowly through mouth as aerosol begins to flow. Then exhale slowly through the mouthpiece. Simply press power switch "off", if treatment needs to be interrupted.
- If an aerosol mask is used, place the mask over mouth and nose. As aerosol begins to flow, inhale deeply and slowly through mouth, then exhale slowly.
- When treatment is complete, turn unit off by pressing the power switch to the "Off" position. Unplug Devilbiss PulmoMate Compressor Nebulizer System from the wall power outlet.
How To Clean Pulmomate Compressor Nebulizer?
PulmoMate Nebulizer Cleaning
- All Pulmomate Nebulizer Parts, except tubing, should be cleaned.
- With power switch in the "Off" position, unplug power cord from wall outlet.
- Disconnect tubing from the air-inlet connector and set aside.
- Disassemble mouthpiece or mask from cap. Open up the nebulizer by twisting cap counter-clockwise and removing baffle.
- In a warm water/dish washing detergent solution wash all items except tubing.
- Rinse under warm tap water for 30 seconds to remove detergent residue.
- Allow to air dry.
PulmoMate Compressor Cleaning
- With power switch in the "Off" position, unplug power cord from wall outlet.
- Wipe clean the compressor cabinet with a damp cloth every few days to keep it dust-free.
Specifications of Pulmomate 4650D
Particulars | Dimensions |
Size | 7.5" W x 3.8" H x 13" D |
Electrical requirements | 2.5amps, 115VAC 60Hz |
Sound level | 53-57 dBA |
Power consumption | 140W maximum |
Maximum compressor pressur | 35 psig |
Compressor free air flow | 13 lpm |
Operating temperature range | +40? to +104?F (+5 to +40?C) |
Operating Humidity | up to 95% non-condensing |
Storage/Transport Temperature Range | -40? to +158?F (-40? to +70?C) |
Storage/Transport Humidity | up to 95% non-condensing |
Supplied Nebulizer Nebulization Rate | 0.15 ml/min or greater |
Supplied Nebulizer MMAD | 5 microns or less |
Supplied nebulizer capacity | 10 ml (cc) |