Shopping Cart: 0 items
Your cart is empty.
MENU
DeVilbiss IntelliPAP 2 CPAP Machine - DV64D-HH
  • DeVilbiss IntelliPAP 2 CPAP Machine - DV64D-HH
  • DeVilbiss IntelliPAP 2 CPAP Machine - DV64D-HH
  • DeVilbiss IntelliPAP 2 CPAP Machine - DV64D-HH
  • DeVilbiss IntelliPAP 2 CPAP Machine - DV64D-HH

DeVilbiss IntelliPAP 2 CPAP Machine - DV64D-HH

DV64D-HH

DeVilbiss IntelliPAP 2 Auto CPAP Machine With Heated Humidifier - ( DV64D-HH )   DeVilbiss IntelliPAP 2 AutoAdjust Auto CPAP Machine ( DV64D-HH ) With Heated Humidifier is a travel-sized CPAP machine designed to automatically adjust pressure during the night. The machine uses multiple techniques to track therapy effectiveness including an SD card, Bluetooth technology, and Smar...


$730.99
Prescription Required
Already on file
I will email to: prescription@eemedicals.com
I will fax 770-485-6251

DeVilbiss IntelliPAP 2 Auto CPAP Machine With Heated Humidifier - ( DV64D-HH )
 

DeVilbiss IntelliPAP 2 AutoAdjust Auto CPAP Machine ( DV64D-HH )
With Heated Humidifier is a travel-sized CPAP machine designed to automatically adjust pressure during the night. The machine uses multiple techniques to track therapy effectiveness including an SD card, Bluetooth technology, and SmartCode. Offers a smaller footprint when machine and humidifier are stacked together. The brightness of the controls and the display can be adjusted independently and have both active and standby brightness settings.


DeVilbiss IntelliPAP 2 AutoAdjust Auto CPAP Machine With Heated Humidifier includes:

  • - Carrying Case
  • - 6 Foot Long 15mm Slim Tubing
  • - Filter Cover
  • - Reusable Filter
  • - Disposable Filter
  • - SD Card
  • - Power Supply
  • - Power Cord
  • - Manual

 

PureView Auto Adjust Algorithm:

  • - It is a unique feature used on the machine to detect advanced apnea events such as periodic breathing and flow limitation
  • - Uses a logic that understands complex issues, leading to automatic changes in pressure in response to OSA and CSA events
  • - Operate between a low and high-pressure range, remaining at the lower pressure until an event is detected requiring a higher pressure

Large LCD Screen Display

  • - Increases the visibility of displayed information and pairs with a knob that is turned and pressed for easy navigation of menus and settings
  • - The display can also show regular reminders to change filters and clean equipment if desired
  • - When in standby, the machine will display a clock and also has an alarm clock function
  • - On-Screen Data includes AHI, leak rate, and usage information

SmartCode Adherence Score

  • - SmartCode messages begin to display on the screen after the first night of therapy
  • - Each code is a uniquely encrypted code holding personal sleep data results
  • - SmartCode is intended to help IntelliPAP 2 users become compliant
  • - SmartCode Adherence is determined after the machine is used for 30 consecutive days
  • - Data can be generated to depict results from1 Day, 7 Days, 30 Days, 90 Days, a cumulative report

Bluetooth Capable Technology

  • - Enable the Bluetooth feature to begin pairing the IntelliPAP 2 to the SmartLink app
  • - The SmartLink Data Management System is designed for use on Apple and Android devices
  • - To begin using the app, visit the iTunes App Store or the Google Play Store depending on the device
  • - Search DeVilbiss SmartLink to locate the SmartLink app
  • - Once the app has been downloaded and the Bluetooth option is turned ON, data will begin streaming from the machine to the handheld device
  • - The SmartLink app is compatible with iPhone, iPad or iPod touch running Apple iOS 8 or newer and Android smartphones and tablets running 4.0.3 or newer

SmartFlex and Adjustable Rounding

  • - Designed to decrease pressure during exhalation 1, 2, or 3 cm for a more comfortable breathing pattern during therapy
  • - Adjustable rounding allows the user to customize the transition between exhalation to inhalation and inhalation to exhalation
  • - The machine settings range from 0 to 5
  • - Level 0 represents a direct jump in pressure, while level 5 represents the softest transition

Ramp Comfort Feature

  • - Designed to gradually increase therapy to the lower pressure of the auto range over a period of time
  • - Between 0 to 45 minutes, the machine will slowly raise the pressure to help the user become acclimated to their therapy so they may fall to sleep with ease
  • - The ramp button is on top of the machine and to the right of the humidifier symbol
  • - Use the button to start or stop ramp

Note: If the machines lower pressure of the auto range is 3, ramp will not be available

Auto Start / Auto Stop

  • - Allows the user to begin and finish CPAP therapy without manually pressing a button
  • - When enabled, place the mask against the face and begin breathing into the mask to start sleep therapy
  • - Likewise, remove the mask when waking to stop sleep therapy
  • - If it is not desired, the machine is equipped with a button to manually control the device

Heated Humidifier

  • - Humidifiers attach to the base of the machine, so only the height is increased with the two are used together
  • - Warm, moist air travels through the hose to the mask to provide comfort to the user
  • - A standard heated humidifier can be set to a level ranging from 0-5 and will heat to provide that level of moisture all night long during inhalation and exhalation
  • - Level 0 provides no heat, while level 5 provides the most heat
  • Also Available (Separately): 

 

More Information about CPAP machines:

 Air Supply Port Cover

  • - When the IntelliPAP 2 machine and humidifier are connected, the air supply port cover folds into the circular crevice located on the back of the IntelliPAP 2 machine
  • - If using the IntelliPAP 2 machine without the humidifier, reposition the air supply port cover so it coats the circular opening found on the bottom of the IntelliPAP 2 machine

Note: The cover must be put back into the opening found on the back of the machine when preparing to reconnect the machine and humidifier

  • - If the cover is still protecting the hole on the bottom of the machine, the devices will not fasten

Water Chamber Cleaning Tips

  • - The water chamber for the IntelliPAP 2 Heated Humidifier needs to be cleaned daily
  • - Note: The water chamber may be placed in the dishwasher for an occasional cleaning
  • - When placed in the dishwasher, the chamber must sit on the top rack
  • - For all other daily needs, hand wash the chamber with warm water and mild soap
  • - Before cleaning the chamber, the user will need to remove the tank from the humidifier cradle

Steps to withdraw the chamber

  • - Gently press on the chamber release latch which is located at the front of the chamber
  • - Slide the chamber out of the cradle Locate and push forward on the chamber disassembly lever which is directly behind the chamber release latch
  • - The chamber will open into two halves

Instructions for Filling the Water Chamber

  • - When refilling the water chamber, use distilled water to help prevent mineral build-up
  • - The IntelliPAP 2 water chamber has water level indicators located on the sides and top of the chamber
  • - Do not surpass the specified markings when refilling the chamber, as it may cause water damage

Sealing Gasket Maintenance

  • - Before each use, examine the sealing gasket surrounding the circumference of the chamber
  • - Ensure the gasket has been put back into place after each cleaning

Cleaning Tips for the Humidifier Cradle

  • The cradle which holds the water chamber should be cleaned weekly

Note: The cradle should not be submerged in water Instead, use a moist cloth to wipe the exterior of the unit;

Steps when preparing to clean the cradle

  • - Remove the power source to allow the heater plate to cool
  • - The cooling process may take up to 10 minutes
  • - Once cooled, withdraw the water chamber from the inside of the cradle
  • - Use the flow generator release button to separate the IntelliPAP 2 machine from the cradle base
  • - Use a moist towel to cleanse the cradle

Specifications of Machine:

Particulars Specifications
Dimensions of Machine  11.7"L x 7.6"W x 3.3"H
Power Supply 65W, 100 - 240V, 50/60 Hz
DC Electrical Requirements 11 - 17 VDC, 5.2 Amps
Pressure Range 3 - 20 cm H2O (0.5cm increments)
Operating Temperature Range 41F to 104F (5c to 40C)
Operating Humidity Range 15% to 93% RH non-condensing
Operating Atmospheric Conditions 1060 hPa - 700 hPa
Storage and Transportation Temperature Range -13F to 158F
Storage and Transportation Humidity Range 15% to 93% RH non-condensing
Sound Pressure Level <26.6 dBA
Sound Power Level <34.6 dBA
Carry Bag Dimensions 11"L x 5.5"W x 8.5"H

 

Warranty of DeVilbiss IntelliPAP 2 CPAP:

3 Year Warranty at EEMEDICALS.

 

THIS ITEM REQUIRES A PRESCRIPTION
If you do not have a prescription at time of purchase, a sales associate will reach out to you prior to delivery.

Current Reviews: 0